Promover la "Iniciativa de la Franja y la Ruta", reducir la presión regulatoria sobre el gobierno, ahorrar costos operativos de las empresas y facilitar el comercio internacional.
Cummins diesel generator sets adopt Cummins' globally unified design, production, and testing standards, providing customers with reliable and integrated one - stop power generation systems, which perform excellently in normal, standby, and continuous operation.
Comply with ISO8528 - 2005 and GB/T2820 - 2009 《Reciprocating Internal Combustion Engine - Driven Alternating - Current Generating Sets》 standards.
The design and manufacturing units of the generator sets have all passed ISO9001 or ISO9002 certification.
Cummins provides a 1 - year or 1000 - hour (whichever comes first) quality guarantee for the generator sets and is responsible for the maintenance of the generator sets, including the engine, generator, and control system.
The professional service network across the country provides customers with 24 - hour after - sales service and technical support.
Performance Features
Longer stroke: The expansion of combustion gas is more sufficient, increasing the effective power output, ensuring low fuel consumption under strong power.
Advanced 4 - valve structure: Strong power, thorough air - fuel combustion, low fuel consumption, and increased low - speed torque, with good power performance and high work efficiency.
Belt - driven cooling and calibration mode: Can withstand high mechanical and thermal loads, with good strength.
Reinforced cylinder block design: Low noise and vibration.
Central - arranged fuel injector and Y - type combustion chamber: Ensure uniform mixture in the cylinder and more complete combustion.
Advanced design: The power - to - weight ratio can reach 30.0kW/L, with a reasonable machine structure and more convenient maintenance.
Standard Configuration
Engine part: Engine, fuel filter, air filter, engine oil filter, charger, starting motor.
Generator part: Generator, air circuit breaker.
Control system: LCD display control panel, electronic speed regulator.
Other parts: Water - cooled radiator, steel base, shock absorber.
Optional parts: Muffler, battery, power cable, oil machine, anti - vibration pad.
Environmental Requirements
Environmental Indicator | Parameter | Environmental Indicator | Parameter |
Altitude (m) | ≤1000 | Water quality pH value | 6.5 - 8 |
Fuel standard | 0# light diesel | Relative humidity | ≤60% |
Atmospheric pressure (kPa) | ≥89.9 | Surface mildew - proof grade | ≤GB/T2423.16/2 level |
Engine oil standard | CF grade / 15W - 40 | Vibration resistance intensity | Horizontal acceleration 0.2g, vertical acceleration 0.1g |
Inlet air temperature (℃) | ≤40 |
Generator Set Parameters
Generator Set Parameter | Value | Generator Set Parameter | Value |
Model | Mobile power station | Transient voltage regulation rate | ≤ - 15% / + 20% |
Machine type number | KC200GF | Steady - state voltage regulation rate | ≤ ± 1% |
Standby power (KW) | 200 | Voltage stabilization time | ≤3sec |
Rated power (KW) | 180 | Voltage deviation | ≤0.5% |
Trailer size (mm) | 3600×2000×3000 | Voltage waveform distortion degree | ≤8% |
Weight (kg) | 4015 | Steady - state frequency regulation rate | ≤5% |
Rotational speed (r/min) | 1500 | Transient frequency regulation rate | ≤ - 10% / + 12% |
Fuel consumption (g/kw.h) | 207 | Frequency stabilization time | 3sec |
Noise (LP7m) (dB) | 70 - 85 | Frequency fluctuation | ≤1.5% |
Engine Parameters
Engine Parameter | Value | Engine Parameter | Value |
Engine brand | Cummins | Engine oil capacity (L) | 27.6 |
Manufacturer | Dongfeng Cummins Engine Co., Ltd. (DCEC) | Cooling water capacity (L) | 35 |
Engine model | 6LTA8.9 - G2 | Fuel system | P1700 straight - line pump |
Standby power (KW) | 220 | Cooling method | Closed water circulation |
Arrangement/Row form | 6 - cylinder/in - line | Speed regulation method | Electronic speed regulation |
Compression ratio | 16.0:1 | Start - up method | DC24V electric start |
Bore×Stroke (mm) | 114×145 | Air intake method | Turbocharged, air - to - air intercooled |
Displacement (L) | 8.9 | Type | Four - stroke |
Engine oil pressure (kPa) | 276 - 414 | Constant load steady - state fluctuation | ≤ ± 0.25% |
Engine oil temperature (℃) | ≤121 | Power deviation | ≤ ± 5% |
Generator Parameters
Generator Parameter | Value | Generator Parameter | Value |
Generator brand | Wuxi Stanford/Stanford | Insulation class | H class |
Manufacturer | Cummins Generator Technology (China) Co., Ltd. | Power factor | COSφ = 0.8 lagging |
Generator model number | UCI274J | Voltage drop factor | TIF: < 50 |
Capacity | 260KVA | Connection | "Y" - type connection |
Voltage | 400V/230V | Radio interference level | THF: < 2% |
Form | Brushless, single - bearing, rotating magnetic field | Excitation system | Self - excitation, automatic voltage regulation |
Winding structure | 2/3 pitch | Compliance standard | Meets BS800 and VDE G, N levels; GB755, BS5000 Part 3, VDE0530, NEMA MG1 - 22, IEC - 34, GSA C22 - 100, AS1359 |
Executive Standards
Standard Type | Standard Number | Standard Type | Standard Number |
Military standard | GJB 5785 - 2006 | Industry standard | JB/T 10303 - 2001 |
National standard | GB/T 2820 - 2002 | Environmental protection certification | Noise and exhaust level/waste gas level |
Telecommunications standard | YD/T 502 - 2007 | Quality system certification | YD/T502 - 2007* |